Stage

DTAC + PT Project

Function

Mixt

Location

Craiova

Height regime

P

Developed area

11 230 m2

The center is composed of 3 distinct buildings as follows:

  • Buildings A and B are laminated steel halls with two adjacent openings of 54 meters.
  • The C building is a 13x46m P+1 building made of reinforced concrete with slender shear walls.
  • Building D has a height regime of P+1 inscribed in a rectangle 54x24m, with a laminated steel structure, located inside the B building.

The main building (A+B) was designed using 2 solutions:

1) Solution with I section elements

The structure of the hangar has an in-plane rectangular shape with dimensions of 66x108m and a height at the ridge of 17.05 m and at the cornice 14.90 m (at the structure). The building has two adjacent openings of 54m and 11 bays of 6.00m.

The envelope walls are made of lightweight panels at the fronts and the roof is made of coffered metal sheet with thermal insulation over which the waterproofing of the welded membranes is placed.

2) Solution with spatial trusses

The structure of the hangar has an in-plane rectangular shape with dimensions of 65.80x109m, has the height at the ridge of 21.36 m and at the cornice 19.75m (at the structure). The building has two adjacent openings of 54m and 7 bays of 10.80m.

The envelope walls are made of lightweight panels at the fronts and the roof is made of coffered metal sheet with thermal insulation over which the waterproofing of the welded membranes is placed.

Do you have a similar project? Get in touch with us!

Contact us